Modular Rectifier Series MRC EFORE for OPUSC
Efore Rectifier MRC1100-1600 from 1100W 24Vdc model up to 1600W 48/60/110/125/220 Vdc Models
- Fanless convection cooling
- Available in 24, 48, 60, 110, 125 & 220 VDC standard output variants
- 1600W max output power (1100W for 24 VDC models)
- Constant output power characteristics with active load sharing
- Nominal 230 VAC input, 140-290 VAC
- Digital communication via CAN bus
- Internal over temperature protection
- Flexible design with full front cabling
- EMC: EN 300 386
- Safety: IEC/EN 60950-1, CB certified
Applications




The Efore 1.6kW MRC AC / DC rectifier series has been specifically designed and optimized for power, industrial and telecommunications applications. Compatible with the product family of OPUS C rack and sub rack 19 "products. These rectifiers have natural convection cooling, limiting the flow of dust that could impact the life of the components as well as obviate the reduced reliability of the fan solutions. The modular structure of this solution allows to customize complete DC UPS solutions to better adapt to the contingent needs of the end users and meet new different requirements in the future, thus optimizing the investments in the back up power structure as well as the possible implementation fo redundancy N+1 with minimum reserve power module. The MRC rectifiers offer 1600W power for models with output voltage 48, 60, 110, 125 and 200 Vdc. The 24 Vdc model can supply 1100W. The rectifier input is single-phase at 140 - 275 VAC. The VIDI system controller allows complete and remote management of the MRC rectifiers systems.The MRC can be used as standalone module with or without battery backup.
Model Number | Power Out Max (W) | Input Voltage (VAC) | V1 Out Nom (V) | Output Current Max (A) | Cooling |
MRC24-1100 | 1100 | 180 - 275 | 24 | 45 | Convection |
MRC48-1600 | 1600 | 180 - 275 | 48 | 33 | Convection |
MRC60-1600 | 1600 | 180 - 275 | 60 | 26 | Convection |
MRC110-1600 | 1600 | 180 - 275 | 110 | 14.5 | Convection |
MRC125-1600 | 1600 | 180 - 275 | 125 | 12.8 | Convection |
MRC220-1600 | 1600 | 180 - 275 | 220 | 7.2 | Convection |
The Efore 1.6kW MRC AC / DC rectifier series has been specifically designed and optimized for power, industrial and telecommunications applications. Compatible with the product family of OPUS C rack and sub rack 19 "products. These rectifiers have natural convection cooling, limiting the flow of dust that could impact the life of the components as well as obviate the reduced reliability of the fan solutions. The modular structure of this solution allows to customize complete DC UPS solutions to better adapt to the contingent needs of the end users and meet new different requirements in the future, thus optimizing the investments in the back up power structure as well as the possible implementation fo redundancy N+1 with minimum reserve power module. The MRC rectifiers offer 1600W power for models with output voltage 48, 60, 110, 125 and 200 Vdc. The 24 Vdc model can supply 1100W. The rectifier input is single-phase at 140 - 275 VAC. The VIDI system controller allows complete and remote management of the MRC rectifiers systems.The MRC can be used as standalone module with or without battery backup.
Model Number | Power Out Max (W) | Input Voltage (VAC) | V1 Out Nom (V) | Output Current Max (A) | Cooling |
MRC24-1100 | 1100 | 180 - 275 | 24 | 45 | Convection |
MRC48-1600 | 1600 | 180 - 275 | 48 | 33 | Convection |
MRC60-1600 | 1600 | 180 - 275 | 60 | 26 | Convection |
MRC110-1600 | 1600 | 180 - 275 | 110 | 14.5 | Convection |
MRC125-1600 | 1600 | 180 - 275 | 125 | 12.8 | Convection |
MRC220-1600 | 1600 | 180 - 275 | 220 | 7.2 | Convection |